  terminals 75 why sta-kon terminals are better like any other value added manu- facturing process, using the best material is only a start. our sta- kon terminals are all manufac- tured with the customer in mind, not a price tag! the following product features are usually absent in competitive products. chamfered/funneled terminal barrel entry this feature makes wire insertion faster and easier. chamfering eliminates wire strand hang up and departure upon insertion into the terminals barrel. the loss of even a couple of wire strands can have negative results on electrical efficiency and resistance to mechanical strain. deep internal serrations after the insertion of a wire into the terminals barrel, a deep ser - rated interior insures a large area of contact which lowers the resis- tance of a connection. upon the mechanical force of tool applied pressure, the wire strands cold flow into the serrated interior. this guarantees electrical resis - tance lower than the wire to which it is applied. this feature also prevents pullout from vibra- tion and mechanical strain. deep internal serrations can be com- pared to the effective holding power of a well treaded tire on a wet highway. sta-kons long barrel design if lowering electrical resistance, preventing wire pullout, eliminat - ing a missed crimp and an insu- lator that stays on the barrel dur - ing installation are your goals, then, you must design a terminal with a long barrel. the fact is that most competitive barrel lengths range from 20%-50% shorter than the sta-kon. the results are usually a stream of electrical fail - ure, rework and added expense. this also provides the insulator with additional surface area, hold - ing tight to the barrel. many com - petitive insulators come off during crimping due to a limited barrel length. platings/finish electroplated-tin is standard. all others require minimum order quantities and are generally not stocked. alternative platings as follows: gold, silver, tin-alloys, nickel, etc. the following finishes are avail - able on most 1-piece sta-kon ter- minals: finish suffix spec. gold plate gp mil-g-45204 type ii, grade b, c, d, class o nickel plate np qq-n-290 class 2, grade g plain finish pf none silver plate sp mil-t-16366 type i or ii, 400 f, 204 c tin plate tp mil-t-10727 type i to order add the indicated suffix to the regular catalog number. telecom 1-800-685-9452
terminals 76 why sta-kon terminals are better?ontinued anti-rotational tongues this is a unique feature to the thomas & betts ring tongue ter- minal. this design prevents termi- nal shorting by keeping the termi - nal secure in the terminal block. the installer can place a greater number of terminals, closer together without worry. brazed or overlapped seam a long barrel design is of little value unless it is one solid piece. that is why thomas & betts brazes the seam on our vinyl insu- lated sta-kon and overlaps the seam on nylon insulated terminals. many competitive terminals have butted seams. this means increased chances for wirestrand loss, poor resistance, wire pullout and electrical failure. if the installer doesnt position the tool exactly on the correct spot on the barrel, theres likely going to be an improper termination. the butted seam can also fold due to tool-applied pressure piercing the terminals insulation from the inside out. with a brazed or over - lapped seam the installer can crimp anywhere along the barrels surface providing up to 2 1 M 2 times the tensile strength of a butted seam terminal, guaranteeing prop- er electrical flow, void free. selective annealing because of the mechanical strength of copper, an installer can experience fatigue associated with repeated installations. for this reason thomas & betts puts our terminals through one more step called selective annealing. this process leaves the barrel soft enough to crimp and form around the wire. however, we cold form the tongue during the manufacturing process so it remains strong. this is done so the tongue can withstand repeated bends and bolt tightening strain common in most electrical instal- lations. many competitors attempt to accomplish similar goals by removing valuable material or using a softer copper which has lower conductivity. this increases electrical resistance as well as the odds for shorting and down- time. telecom 1-800-685-9452
terminals 77 erg-2001 flat bottom box center reinforced spring detent for minimum insertion force complete identification electro tin plate brazed seam crimp produces even compression forces on insulation and stranding strands enter as a homogeneous group and compact tightly under compression due to fully brazed seam vinyl brazed seam, or nylon/tefzel* insulated grip sleeve serrated inner barrel for maximum contact & tensile strength hardened tongue selectively annealed long barrel color-coded tefzel*, nylon, or vinyl complete wire & stud size identification anti-rotational tongue compound spring rails provide positive contact after repeated insertions & funneled wire entrance extra-length insulation sleeve thomas & betts developed the first tool-applied solderless terminals and connectors nearly 50 years ago in response to industry awareness of the need for better performance of electrical systems. today, sophisticated electrical and electronic equipment requires an even higher degree of reliability. here are key factors built into the sta-kon terminal and connector line that deliver this reliability: ? broad product selection ? job suited tooling ? testing and approvals ? field proven performance ? new product development ? service and availability sta-kon technical data terminals & splices u.l. 94 insulation rating flammability voltage temperature nylon v-2 600v** 105 c vinyl v - 0 600v** 105 c tefzel* v-0 600v** 150 c **1000v fixture or sign disconnects 300v 105 c sta-kon disconnects ? internal barrel serrations and long barrel provide for maximum tensile strength ? complete line of installing tools, engineered to match tool with terminal ? funnel entry insulators allow for easier inserting of wire into barrel ? color-coded for easy installation sta-kon ring, fork & locking fork ? complete line of installing tools engineered to match tool with terminal ? first to gain military approval for pressure connections many styles available for military applications ? sta-kon products exceed test specification requirements of mil- itary, u.l. and csa ? tefzel* & nylon terminals provided with extra metal sleeve to grip insulation ? vinyl insulated and bare sta-kons feature brazed seam wire barrels which can be crimped at any place on the barrel circumference the shure stake tools are matched to terminals the shure stake mechanism prevents the dies from releasing the termi- nal until the proper compression has been completed. with this method, an operator achieves a reliable crimp everytime. telecom 1-800-685-9452
terminals the proper installation procedure for the quality assured connection the proper installation of termi - nals, splices and connectors is very important to the efficient performance of an electrical sys- tem. the properly installed con - nector will allow good conductivi - ty through the termination. a poor termination results in a high resistance connection. a poor connector installation may cause damage or failure of an entire system. certain basic require- ments must be met to make a good termination. 1. before the connector or terminal is installed on the con - ductor, follow these recom- mended practices: ? strip the insulation care - fully so as to avoid nicking or cutting conductor strands ? strip the insulation to the proper length so that the con - ductors can be inserted fully into the connector barrel; the wire/cable should be visible in the inspection hole of the lug; the proper strip length can be found on page 49d. 2. thomas & betts wire strippers will help eliminate these prob- lems by prop- erly gaging and mea- suring the depth and length requirements for the conductor. see page 44d for wire strippers. performance data voltage drop test 500 cycles thomas & betts terminals show consistently lower millivolt drops than those allowed by nema speci- fication. wire pullout tension test thomas & betts terminals show consistently higher wire retention forces than those required by nema specification. 78 30 28 24 20 16 12 8 4 0 8 16 24 32 40 48 amps 22 20 18 16 14 12 10 awg voltage drop (mv) code typical test value of t&b terminals nema requirement 120 100 80 60 40 0 22 20 18 16 14 12 10 wire size (awg) wire pullout force (lbs.) code typical test value of t&b terminals nema require- ment stripped wire stripping length indentor orient tongue as shown rest terminal telecom 1-800-685-9452
terminals 79 the sta-kon terminal numbering system distributor package 100/50 bulk ?.e.m.?packaged 1000/500 common to both packages letter a denotes 22-18 awg wire range letter b denotes 16-14 awg wire range letter c denotes 12-10 awg wire range letter r preceding the above let- ters indicates the terminal is insu- lated no letter r no insulation ?no exception! distributor packaged part numbers are very descriptive indicating insulation and type, stud size, tongue style and the largest maximum wire that can be put inside. if the letter r precedes the number the part is nylon insulated?a18-6 if the letter r follows the number the part is vinyl insulated?4rb-8 installation procedure 1. twist the wires to eliminate fanning of strands. 2. open tool handles fully. 3. insert terminal in prop - er die nest and locate it as shown above. when crimping a butt splice, position in proper die nest with window facing indentor. 4. close handles slightly to secure terminal. do not deform terminal. 5. insert properly stripped wire into terminal. 6. complete crimp by clos- ing handles. stripped wire stripping length indentor orient tongue as shown rest terminal telecom 1-800-685-9452
nylon terminals nylon insulated ring?nsulation grip wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m rz22-2** 100 26-22 .083 # 2 1 .57 .14 .13 .49 rz22-4** 100 26-22 .083 # 4 1 .65 .21 .20 .54 rz22-6** 100 26-22 .083 # 6 1 .65 .21 .20 .54 rz22-8** 100 26-22 .083 # 8 1 .75 .25 .23 .62 rz22-10** 100 26-22 .083 # 1 0 1 .75 .25 .23 .62 rax23* 1000 26-24 .125 # 2 3 .66 .14 .14 .59 rax43* 1000 26-24 .125 # 4 3 .74 .20 .19 .64 rax63* 1000 26-24 .125 # 6 3 .84 .25 .22 .72 rax83* 1000 26-24 .125 # 8 3 .84 .25 .22 .72 rax103* 1000 26-24 .125 # 1 0 3 .84 .25 .24 .72 ra18-4 100 22-16 .136 # 4 2 .70 .23 .14 .59 ra323 1000 22-16 .136 # 4 2 .70 .23 .14 .59 ra333 1000 22-16 .136 # 6 2 .70 .23 .14 .59 ra18-6 100 22-16 .136 # 6 2 .83 .26 .25 .71 ra853 1000 22-16 .136 # 6 2 .83 .26 .25 .71 ra18-8 100 22-16 .136 # 8 3 .83 .26 .25 .71 ra833 1000 22-16 .136 # 8 3 .83 .26 .25 .71 ra863 1000 22-16 .136 # 8 3 .83 .26 .25 .71 ra18-10 100 22-16 .136 # 1 0 2 .86 .31 .25 .71 ra873 1000 22-16 .136 # 1 0 2 .86 .31 .25 .71 ra18-14 100 22-16 .136 1 M 4 " 3 1.07 .46 .31 .84 ra713 1000 22-16 .136 1 M 4 " 3 1.07 .46 .31 .84 ra18-516 100 22-16 .136 5 M 16 " 3 1.07 .46 .31 .84 ra723 1000 22-16 .136 5 M 16 " 3 1.07 .46 .31 .84 ra18-38 100 22-16 .136 3 M 8 " 3 1.17 .53 .35 .87 ra733 1000 22-16 .136 3 M 8 " 3 1.17 .53 .35 .87 ra18-12 100 22-16 .136 1 M 2 " 3 1.27 .72 .50 .92 ra753 1000 22-16 .136 1 M 2 " 3 1.27 .72 .50 .92 rb14-4 100 18-14 .162 # 4 2 1 M 2 .72 .26 .14 .59 rb1323 1000 18-14 .162 # 4 2 1 M 2 .72 .26 .14 .59 rb14-6 100 18-14 .162 # 6 3 .89 .31 .25 .71 rb853 1000 18-14 .162 # 6 3 .89 .31 .25 .71 rb1333 1000 18-14 .162 # 6 3 .74 .26 .14 .59 rb14-8 100 18-14 .162 # 8 3 .89 .31 .25 .71 rb863 1000 18-14 .162 # 8 3 .89 .31 .25 .71 rb14-10 100 18-14 .162 # 1 0 3 1 M 2 .89 .31 .25 .71 rb873 1000 18-14 .162 # 1 0 3 1 M 2 .89 .31 .25 .71 rb14-14 100 18-14 .162 1 M 4 "3 1 M 2 1.08 .47 .31 .81 rb713 1000 18-14 .162 1 M 4 "3 1 M 2 1.08 .47 .31 .81 rb14-516 100 18-14 .162 5 M 16 "3 1 M 2 1.08 .47 .31 .84 rb723 1000 18-14 .162 5 M 16 "3 1 M 2 1.08 .47 .31 .84 rb14-38 100 18-14 .162 3 M 8 "3 1 M 2 1.17 .53 .35 .87 rb733 1000 18-14 .162 3 M 8 "3 1 M 2 1.17 .53 .35 .87 rb14-12 100 18-14 .162 1 M 2 " 4 1.25 .72 .50 .90 rb753 1000 18-14 .162 1 M 2 " 4 1.25 .72 .50 .90 rc10-6 5 0 12-10 .210 # 6 3 1.00 .37 .27 .81 rc333 500 12-10 .210 # 6 3 1.00 .37 .27 .81 rc10-8 5 0 12-10 .210 # 8 5 1.00 .37 .27 .81 rc863 500 12-10 .210 # 8 5 1.00 .37 .27 .81 rc10-10 5 0 12-10 .210 # 1 0 5 1.00 .37 .27 .81 rc363 500 12-10 .210 # 1 0 5 1.00 .37 .27 .81 rc10-14 5 0 12-10 .210 1 M 4 " 6 1.12 .53 .32 .86 rc713 500 12-10 .210 1 M 4 " 6 1.12 .53 .32 .86 rc10-516 5 0 12-10 .210 5 M 16 " 6 1.21 .53 .31 .94 rc703 500 12-10 .210 5 M 16 " 6 1.21 .53 .31 .94 rc10-38 5 0 12-10 .210 3 M 8 " 6 1.27 .59 .35 .98 rc733 500 12-10 .210 3 M 8 " 6 1.27 .59 .35 .98 rc10-12 5 0 12-10 .210 1 M 2 " 6 1.37 .72 .52 1.02 rc753 500 12-10 .210 1 M 2 " 6 1.37 .72 .52 1.02 * not listed by u.l. csa ** csa listed only u.l. listed e9809 installing tools: wt2000, wt112m, wt145c, wt1455, erg-2001, erg-2003, wt145a, wt2130a (rc,rbc) installing tool: wt1452 (rz series only) 80 self-insulated with high dieletric-strength nylon sleeves, these ring terminals are recommended for temperatures up to 105?. an inner bronze insulation grip sleeve lengthens the flexing radius of the conductor and eliminates conduc- tor creep. the nylon jacket is color-coded: color code wire range yellow 26-22 red 22-16 blue 18-14 yellow 12-10 most standard bulk catalog numbers can be put on mylar tape for reel fed applica- tions (i.e. 12050 tool and application dies). please consult tech service. please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) rz & rax stock thickness: .02 ra & rb stock thickness: .03 rc stock thickness: .04 telecom 1-800-685-9452
nylon terminals nylon insulated ring?xpanded insulation grip wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m rb14-4x 100 18-14 .190 # 4 4 .80 .26 .14 .67 rb1324 1000 18-14 .190 # 4 4 .80 .26 .14 .67 rb14-6x 100 18-14 .190 # 6 4 .95 .31 .25 .79 rb854 1000 18-14 .190 # 6 4 .95 .31 .25 .79 rb14-8x 100 18-14 .190 # 8 5 .95 .31 .25 .79 rb864 1000 18-14 .190 # 8 5 .95 .31 .25 .79 rb14-10x 100 18-14 .190 # 1 0 5 .95 .31 .25 .79 rb874 1000 18-14 .190 # 1 0 5 .95 .31 .25 .79 rb14-14x 100 18-14 .190 1 M 4 " 6 1.16 .47 .31 .92 rb714 1000 18-14 .190 1 M 4 " 6 1.16 .47 .31 .92 rb14-516x 100 18-14 .190 5 M 16 " 6 1.16 .47 .31 .92 rb724 1000 18-14 .190 5 M 16 " 6 1.16 .47 .31 .92 rb14-38x 100 18-14 .190 3 M 8 " 6 1.25 .53 .42 .95 rb734 1000 18-14 .190 3 M 8 " 6 1.25 .53 .42 .95 rc10-6x 5 0 12-10 .250 # 6 5 1.10 .37 .27 .91 rc334 500 12-10 .250 # 6 5 1.10 .37 .27 .91 rc10-8x 5 0 12-10 .250 # 8 5 1.10 .37 .27 .91 rc864 500 12-10 .250 # 8 5 1.10 .37 .27 .91 rc10-10x 5 0 12-10 .250 # 1 0 5 1.10 .37 .27 .91 rc364 500 12-10 .250 # 1 0 5 1.10 .37 .27 .91 rc10-14x 5 0 12-10 .250 1 M 4 " 6 1.22 .53 .32 .96 rc714 500 12-10 .250 1 M 4 " 6 1.22 .53 .32 .96 rc10-516x 5 0 12-10 .250 5 M 16 " 6 1.32 .53 .31 1.05 rc704 500 12-10 .250 5 M 16 " 6 1.32 .53 .31 1.05 rc10-38x 5 0 12-10 .250 3 M 8 " 6 1.38 .59 .35 1.09 rc734 500 12-10 .250 3 M 8 " 6 1.38 .59 .35 1.09 rc10-12x 5 0 12-10 .250 1 M 2 " 6 1.48 .72 .52 1.13 u.l. listed e9809 installing tools: wt2000, wt112m, wt145c, erg-2001, erg-2003, wt145a, wt2130a(rc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) 81 catalog numbers with the suffix x indicate an expanded insulation grip. this means a wider wire entry to accommodate heavy wall insula- tion. ring terminals won? fall free even if the mounting screw loosens. rb stock thickness: .03 rc stock thickness: .04 telecom 1-800-685-9452
nylon terminals 82 nylon insulated ring wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m rd8-10 2 5 9-8-7 .340 # 1 0 1 2 1.48 .42 .28 1.29 rd367 2 0 0 9-8-7 .340 # 1 0 1 2 1.48 .42 .28 1.29 rd8-14 2 5 9-8-7 .340 1 M 4 " 1 2 1.54 .46 .36 1.32 rd717 2 0 0 9-8-7 .340 1 M 4 " 1 2 1.54 .46 .36 1.32 rd8-516 2 5 9-8-7 .340 5 M 16 " 1 2 1.63 .57 .36 1.35 rd727 2 0 0 9-8-7 .340 5 M 16 " 1 2 1.63 .57 .36 1.35 rd8-38 2 5 9-8-7 .340 3 M 8 " 1 2 1.63 .57 .36 1.35 rd737 2 0 0 9-8-7 .340 3 M 8 " 1 2 1.63 .57 .36 1.35 rd8-12 2 5 9-8-7 .310 1 M 2 " 1 2 1.79 .82 .55 1.39 rd757* 2 0 0 9-8-7 .310 1 M 2 " 1 2 1.79 .82 .55 1.39 rd10161 2 0 0 9-8-7an .270 # 8 1 2 1.40 .41 .24 1.20 rd10361 2 0 0 9-8-7an .270 # 1 0 1 2 1.40 .41 .24 1.20 rd10711 2 0 0 9-8-7an .270 1 M 4 " 1 2 1.45 .45 .27 1.22 rd10721 2 0 0 9-8-7an .270 5 M 16 " 1 2 1.53 .56 .34 1.25 rd10731 2 0 0 9-8-7an .270 3 M 8 " 1 2 1.53 .56 .34 1.25 re6-10 2 0 6-5 .420 # 1 0 1 6 1.65 .49 .28 1.40 re267 2 0 0 6-5 .420 # 1 0 1 6 1.65 .49 .28 1.40 re6-14 2 0 6-5 .420 1 M 4 " 1 6 1.65 .49 .28 1.40 re717 2 0 0 6-5 .420 1 M 4 " 1 6 1.65 .49 .28 1.40 re6-516 2 0 6-5 .420 5 M 16 " 1 6 1.76 .61 .34 1.47 re727 2 0 0 6-5 .420 5 M 16 " 1 6 1.76 .61 .34 1.47 re6-38 2 0 6-5 .420 3 M 8 " 1 6 1.76 .61 .34 1.47 re737 2 0 0 6-5 .420 3 M 8 " 1 6 1.76 .61 .34 1.47 re6-12 2 0 6-5 .395 1 M 2 " 1 6 1.83 .82 .55 1.43 re757* 2 0 0 6-5 .395 1 M 2 " 1 6 1.83 .82 .55 1.43 re10261 200 6-5an .315 # 1 0 1 6 1.55 .49 .24 1.31 re10711 200 6-5an .315 1 M 4 " 1 6 1.55 .49 .27 1.31 re10721 200 6-5an .315 5 M 16 " 1 6 1.70 .60 .34 1.40 re10731 200 6-5an .315 3 M 8 " 1 6 1.70 .60 .34 1.40 rf4-10 1 5 4-3 .510 # 1 0 2 1 1.76 .56 .36 1.49 rf267 2 0 0 4-3 .510 # 1 0 2 1 1.76 .56 .36 1.49 rf4-14 1 5 4-3 .510 1 M 4 " 2 1 1.76 .56 .36 1.49 rf717 2 0 0 4-3 .510 1 M 4 " 2 1 1.76 .56 .36 1.49 rf4-516 1 5 4-3 .510 5 M 16 " 2 1 1.84 .62 .35 1.53 rf727 2 0 0 4-3 .510 5 M 16 " 2 1 1.84 .62 .35 1.53 rf4-38 1 5 4-3 .510 3 M 8 " 2 3 1.84 .62 .35 1.53 rf737 2 0 0 4-3 .510 3 M 8 " 2 3 1.84 .62 .35 1.53 rf757* 2 0 0 4-3 .500 1 M 2 " 2 3 1.90 .82 .55 1.49 rf10261 200 4-3an .380 # 1 0 2 6 1.78 .55 .30 1.51 rf10711 200 4-3an .380 1 M 4 " 2 6 1.78 .55 .30 1.51 rf10721 200 4-3an .380 5 M 16 " 2 6 1.80 .62 .34 1.49 rf10731 200 4-3an .380 3 M 8 " 2 6 1.80 .82 .34 1.49 rg2-10 1 0 2-1 .588 # 1 0 4 2 2.15 .69 .40 1.83 rg267 1 0 0 2-1 .588 # 1 0 4 2 2.15 .69 .40 1.83 rg2-14 1 0 2-1 .588 1 M 4 " 4 2 2.15 .69 .40 1.83 rg717 1 0 0 2-1 .588 1 M 4 " 4 2 2.15 .69 .40 1.83 rg2-516 1 0 2-1 .588 5 M 16 " 4 2 2.15 .69 .40 1.83 rg727 1 0 0 2-1 .588 5 M 16 " 4 2 2.15 .69 .40 1.83 rg2-38 1 0 2-1 .588 3 M 8 " 4 2 2.15 .69 .40 1.83 rg737 1 0 0 2-1 .588 3 M 8 " 4 2 2.15 .69 .40 1.83 rg2-12 1 0 2-1 .588 1 M 2 " 4 2 2.35 .80 .49 1.93 rg757 1 0 0 2-1 .588 1 M 2 " 4 2 2.35 .80 .49 1.93 rg9711 100 2an 453 1 M 4 " 4 8 2.07 .69 .40 1.74 rg9731 1 0 0 2 a n .453 3 M 8 " 4 8 2.07 .69 .40 1.74 rg9751 1 0 0 2 a n .453 1 M 2 " 4 8 2.26 .80 .49 1.84 an aircraft wire u.l. listed e9809 installing tools: tbm6/tbm6s, wt2130a (rd series only) note: not available on mylar tape. rd, re, rf stock thickness: .04 rg stock thickness: .05 * brazed seam, lolly-pop style tongue c telecom 1-800-685-9452
nylon terminals nylon insulated ring?ontinued wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m rh9711 1 0 0 1 a n .500 1 M 4 " 5 4 2.14 .77 .44 1.81 rh9731 1 0 0 1 a n .500 3 M 8 " 5 4 2.14 .77 .44 1.81 rh9751 1 0 0 1 a n .500 1 M 2 " 5 4 2.34 .77 .54 1.90 rj9711 100 1/0an .550 1 M 4 " 8 0 2.35 .83 .46 1.97 rj9731 100 1/0an .550 3 M 8 " 8 0 2.35 .83 .46 1.97 rj9751 100 1/0an .550 1 M 2 " 8 0 2.49 .89 .55 2.04 rh717 1 0 0 1/0 .629 1 M 4 " 8 0 2.14 .77 .43 1.81 rh727 1 0 0 1/0 .629 5 M 16 " 8 0 2.14 .77 .43 1.81 rh737 1 0 0 1/0 .629 3 M 8 " 8 0 2.14 .77 .43 1.81 rh757 1 0 0 1/0 .629 1 M 2 " 8 0 2.34 .77 .54 1.90 rk9731 100 2/0an .610 3 M 8 " 7 0 2.52 .93 .55 2.14 rk9751 100 2/0an .610 1 M 2 " 7 0 2.60 .93 .55 2.15 rj717 1 0 0 2/0 .675 1 M 4 " 8 0 2.34 .83 .46 1.96 rj727 1 0 0 2/0 .675 5 M 16 " 8 0 2.34 .83 .46 1.96 rj737 1 0 0 2/0 .675 3 M 8 " 8 0 2.34 .83 .46 1.96 rj757 1 0 0 2/0 .675 1 M 2 " 8 0 2.48 .89 .54 2.03 rl9731 100 3/0an .680 3 M 8 " 1 2 0 2.83 1.04 .57 2.36 rl9751 100 3/0an .680 1 M 2 " 1 2 0 2.83 1.04 .57 2.36 rk717 1 0 0 3/0 .765 1 M 4 " 8 4 2.60 .93 .54 2.21 rk727 1 0 0 3/0 .765 5 M 16 " 8 4 2.60 .93 .54 2.21 rk737 1 0 0 3/0 .765 3 M 8 " 8 4 2.60 .93 .54 2.21 rm9731 100 4/0an .750 3 M 8 " 1 6 0 3.00 1.13 .66 2.51 rm9751 100 4/0an .750 1 M 2 " 1 6 0 3.00 1.13 .66 2.51 rl737 1 0 0 4/0 .785 3 M 8 " 1 3 0 2.83 1.04 .57 2.35 rl757 1 0 0 4/0 .785 1 M 2 " 1 3 0 2.83 1.04 .57 2.35 rm737 100 250mcm .868 3 M 8 " 1 3 0 3.00 1.13 .65 2.51 rm747 100 250mcm .868 7 M 16 " 1 3 0 3.00 1.13 .65 2.51 rm757 100 250mcm .868 1 M 2 " 1 3 0 3.00 1.13 .65 2.51 a naircraft wire u.l. listed e9809 installing tools: tbm6/tbm6s, wt2130a (rd series only) note: not available on mylar tape. 83 stock thickness: rh = .05 rj = .06 rk = .06 rl = .07 rm = .07 telecom 1-800-685-9452
terminals 84 heat shrinkable ring terminals?xpanded insulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m ras18-6x 100 22-18 .170 # 6 2 1.23 .25 .27 1.10 ras18-8x 100 22-18 .170 # 8 3 1.26 .31 .27 1.10 ras18-10x 100 22-18 .170 # 1 0 2 1.26 .31 .27 1.10 rbs14-6x 100 16-14 .200 # 6 3 1.23 .25 .27 1.10 rbs14-8x 100 16-14 .200 # 8 3 1.23 .25 .27 1.10 rbs14-10x 100 16-14 .200 # 1 0 3 1 M 2 1.26 .31 .27 1.10 rcs10-6x 5 0 12-10 .250 # 6 3 1.34 .31 .27 1.15 rcs10-8x 5 0 12-10 .250 # 8 5 1.34 .37 .27 1.15 rcs10-10x 5 0 12-10 .250 # 1 0 5 1.34 .37 .27 1.15 rcs10-14x 5 0 12-10 .250 1 M 4 " 6 1.34 .49 .32 1.15 u.l. listed e9809 installing tool: wt1255 note: not available on mylar tape. these ring terminals are self-insulated with heat shrinkable nylon and internally coated sealant. upon completed installation, a fully sealed connection is achieved to protect the joint against the degrading effects of galvanic action, corrosion, and environmental exposure. ras & rbs stock thickness: .03 rcs stock thickness: .04 telecom 1-800-685-9452
vinyl terminals vinyl insulated ring?nsulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m 18ra-4 100 22-16 .150 # 4 3 .97 .31 .27 .81 ra77 1000 22-16 .150 # 4 3 .97 .31 .27 .81 18ra-6 100 22-16 .150 # 6 3 .94 .25 .27 .81 ra857 1000 22-16 .150 # 6 3 .94 .25 .27 .81 18ra-8 100 22-16 .150 # 8 3 .97 .31 .27 .81 ra867 1000 22-16 .150 # 8 3 .97 .31 .27 .81 18RA-10 100 22-16 .150 # 1 0 3 .97 .31 .27 .81 ra877 1000 22-16 .150 # 1 0 3 .97 .31 .27 .81 18ra-14 100 22-16 .150 1 M 4 " 4 1.13 .50 .37 .88 ra717 1000 22-16 .150 1 M 4 " 4 1.13 .50 .37 .88 18ra-516 100 22-16 .150 5 M 16 " 4 1.13 .50 .37 .88 ra727 1000 22-16 .150 5 M 16 " 4 1.13 .50 .37 .88 18ra-38 100 22-16 .150 3 M 8 " 4 1.24 .54 .37 .91 ra737 1000 22-16 .150 3 M 8 " 4 1.24 .54 .37 .91 14rb-4 100 18-14 .170 # 4 3 .94 .25 .27 .81 rb1327 1000 18-14 .170 # 4 3 .94 .25 .27 .81 14rb-6 100 18-14 .170 # 6 3 .97 .31 .27 .81 rb857 1000 18-14 .170 # 6 3 .97 .31 .27 .81 14rb-8 100 18-14 .170 # 8 3 .97 .31 .27 .81 rb867 1000 18-14 .170 # 8 3 .97 .31 .27 .81 14rb-10 100 18-14 .170 # 1 0 3 .97 .31 .27 .81 rb877 1000 18-14 .170 # 1 0 3 .97 .31 .27 .81 14rb-14 100 18-14 .170 1 M 4 " 4 1.14 .50 .38 .89 rb717 1000 18-14 .170 1 M 4 " 4 1.14 .50 .38 .89 14rb-516 100 18-14 .170 5 M 16 " 4 1.15 .50 .38 .89 rb727 1000 18-14 .170 5 M 16 " 4 1.15 .50 .38 .89 14rb-38 100 18-14 .170 3 M 8 " 4 1.16 .54 .38 .91 rb-737 1000 18-14 .170 3 M 8 " 4 1.16 .54 .38 .91 10rc-6 5 0 12-10 .210 # 6 5 1.06 .31 .27 .90 rc337 500 12-10 .210 # 6 5 1.06 .31 .27 .90 10rc-8 5 0 12-10 .210 # 8 5 1.06 .31 .27 .90 rc777 500 12-10 .210 # 8 5 1.06 .31 .27 .90 10rc-10 5 0 12-10 .210 # 1 0 5 1.06 .31 .27 .90 rc367 500 12-10 .210 # 1 0 5 1.06 .31 .27 .90 10rc-14 5 0 12-10 .210 1 M 4 " 6 1.16 .50 .27 .90 rc717 500 12-10 .210 1 M 4 " 6 1.16 .50 .27 .90 10rc-516 5 0 12-10 .210 5 M 16 " 6 1.17 .50 .37 .92 rc707 500 12-10 .210 5 M 16 " 6 1.17 .50 .37 .92 10rc-38 5 0 12-10 .210 3 M 8 " 6 1.29 .59 .44 .99 rc737 500 12-10 .210 3 M 8 " 6 1.29 .59 .44 .99 u.l. listed e9809 installing tools: wt145c, wt2000, wt112m, erg-2001, erg-2003, wt2130a (rc, rbc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) 85 these ring terminals are self-insulated with a pvc insulation sleeve of extra length to give protection and relieve bending stress at wire? flex point. brazed seam barrel is serrated to obtain high pull-out value. terminal is made of high conductivity electrolytic copper, electro-tin plated. insulation material is color-coded: color code wire range red 22-16 blue 18-14 yellow 12-10 stock thickness: ra & rb = .03 rc = .04 telecom 1-800-685-9452
vinyl terminals vinyl insulated ring?xpanded insulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m 18ra-6x 100 22-16 .170 # 6 3 .97 .31 .27 .81 18ra-8x 100 22-16 .170 # 8 3 .97 .31 .27 .81 ra867-170 1000 22-16 .170 # 8 3 .97 .31 .27 .81 18RA-10x 100 22-16 .170 # 1 0 3 .97 .31 .27 .81 ra877-170 1000 22-16 .170 # 1 0 3 .97 .31 .27 .81 18ra-14x 100 22-16 .170 1 M 4 " 4 1.13 .50 .37 .88 ra727-170 1000 22-16 .170 5 M 16 " 4 1.13 .50 .37 .88 18ra-38x 100 22-16 .170 3 M 8 " 4 1.24 .54 .35 .91 14rb-4x 100 18-14 .200 # 4 3 .94 .25 .27 .81 14rb-6x 100 18-14 .200 # 6 3 .97 .31 .27 .81 rb857-200 1000 18-14 .200 # 6 3 .97 .31 .27 .81 14rb-8x 100 18-14 .200 # 8 3 .97 .31 .27 .81 rb867-200 1000 18-14 .200 # 8 3 .97 .31 .27 .81 14rb-10x 100 18-14 .200 # 1 0 3 .97 .31 .27 .81 rb877-200 1000 18-14 .200 # 1 0 3 .97 .31 .27 .81 14rb-14x 100 18-14 .200 1 M 4 " 4 1.14 .50 .38 .89 rb717-200 1000 18-14 .200 1 M 4 " 4 1.14 .50 .38 .89 14rb-516x 100 18-14 .200 5 M 16 " 4 1.15 .50 .38 .89 14rb-38x 100 18-14 .200 3 M 8 " 4 1.16 .54 .35 .91 10rc-6x 5 0 12-10 .250 # 6 5 1.06 .31 .27 .90 rc337-250 500 12-10 .250 # 6 5 1.06 .31 .27 .90 10rc-8x 5 0 12-10 .250 # 8 5 1.06 .31 .27 .90 rc777-250 500 12-10 .250 # 8 5 1.06 .31 .27 .90 10rc-10x 5 0 12-10 .250 # 1 0 5 1.06 .31 .27 .90 rc367-250 500 12-10 .250 # 1 0 5 1.06 .31 .27 .90 10rc-14x 5 0 12-10 .250 1 M 4 " 6 1.16 .50 .27 .90 rc717-250 500 12-10 .250 1 M 4 " 6 1.16 .50 .27 .90 10rc-516x 5 0 12-10 .250 5 M 16 " 6 1.17 .50 .37 .92 10rc-38x 5 0 12-10 .250 3 M 8 " 6 1.29 .59 .44 .99 rc737-250 500 12-10 .250 3 M 8 " 6 1.29 .59 .44 .99 u.l. listed e9809 installing tools: wt145c, wt2000, wt112m, erg-2001, erg-2003, wt2130a (rc, rbc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) catalog numbers with the suffix x indicate an expanded insulation support. this means a wider wire entry to accommodate heavy wall insulation. ring terminals won? fall free even if the mounting screw loosens. stock thickness: ra & rb = .03 rc = .04 86 telecom 1-800-685-9452
u.l. 94v-0 rated ring terminals 87 vinyl insulated ring max. cat. stud ins. wire dimensions no. size dia. range a b c m series rdv?ircraft wire an rdv10161 # 8 .270 9,8,7 1.40 .41 .24 1.20 rdv10361 # 1 0 .270 9,8,7 1.40 .41 .24 1.20 rdv10711 1 M 4 " .270 9,8,7 1.45 .45 .27 1.22 note: not available on mylar tape. stock thickness: .04 new rd and re sizes now available with a u.l. 94v-o vinyl insulator * brazed seam, lolly-pop style tongue c telecom 1-800-685-9452
tefzel insulated terminals 88 tefzel insulated ring?nsulation grip max. cat. stud ins. wire dimensions no. size dia. range a b c m series rat?or u.l. 94v-o flamability rating/high temperature and chemical resistance. rat853 # 6 .140 22-18 .81 .25 .25 .69 rat863 # 8 .140 22-18 .84 .31 .25 .69 rat873 # 1 0 .140 22-18 .84 .31 .25 .69 rat713 1 M 4 " .140 22-18 1.07 .46 .31 .84 series rbt rbt853 # 6 .170 16-14 .84 .31 .25 .69 rbt863 # 8 .170 16-14 .84 .31 .25 .69 rbt873 # 1 0 .170 16-14 .84 .31 .25 .69 rbt713 1 M 4 " .170 16-14 1.08 .46 .31 .81 series rct rct333 # 6 .210 12-10 1.00 .37 .27 .81 rct863 # 8 .210 12-10 1.00 .37 .27 .81 rct363 # 1 0 .210 12-10 1.00 .37 .27 .81 rct713 1 M 4 " .210 12-10 1.11 .52 .32 .85 rct703 5 M 16 " .210 12-10 1.23 .52 .31 .96 rct733** 3 M 8 " .210 12-10 1.29 .58 .35 1.00 ** not available on tape. u.l. listed e9809 installing tools: erg2001, wt112m, wt145c. most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) stock thickness: rat & rbt = .03 rct = .04 package quantities: rat & rbt = 1000 pcs. rct = 500 pcs. telecom 1-800-685-9452
non-insulated terminals 89 non-insulated ring wt./lbs. cat. pkg. wire bolt per dimensions no. qty. range hole 1000 a b c m a18-4 100 22-16 # 4 2 .75 .31 .27 .59 a18-6 100 22-16 # 6 2 .72 .25 .27 .59 a85 1000 22-16 # 6 2 .72 .25 .27 .59 a18-8 100 22-16 # 8 2 .75 .31 .27 .59 a86 1000 22-16 # 8 2 .75 .31 .27 .59 a18-10 100 22-16 #10 2 .75 .31 .27 .59 a87 1000 22-16 #10 2 .75 .31 .27 .59 a18-14 100 22-16 1 M 4 " 3 .92 .50 .37 .67 a71 1000 22-16 1 M 4 " 3 .92 .50 .37 .67 a72 1000 22-16 5 M 16 " 3 .92 .50 .37 .67 a73 1000 22-16 3 M 8 " 3 .99 .54 .35 .67 a18-12 100 22-16 1 M 2 " 3 1.06 .72 .38 .70 a75 1000 22-16 1 M 2 " 3 1.06 .72 .38 .70 b14-4 100 18-14 # 4 2 .72 .25 .27 .59 b132 1000 18-14 # 4 2 .72 .25 .27 .59 b14-6 100 18-14 # 6 2 .75 .31 .27 .59 b133 1000 18-14 # 6 2 .75 .31 .27 .59 b14-8 100 18-14 # 8 3 .75 .31 .27 .59 b86 1000 18-14 # 8 3 .75 .31 .27 .59 b14-10 100 18-14 #10 3 .75 .31 .27 .59 b87 1000 18-14 #10 3 .75 .31 .27 .59 b14-14 100 18-14 1 M 4 " 6 .93 .50 .38 .68 b71 1000 18-14 1 M 4 " 6 .93 .50 .38 .68 b14-516 100 18-14 5 M 16 " 6 .93 .50 .38 .68 b72 1000 18-14 5 M 16 " 6 .93 .50 .38 .68 b14-38 100 18-14 3 M 8 " 6 .96 .54 .35 .68 b73 1000 18-14 3 M 8 " 6 .96 .54 .35 .68 b14-12 100 18-14 1 M 2 " 6 1.06 .72 .38 .70 b75 1000 18-14 1 M 2 " 6 1.06 .72 .38 .70 b85 1000 18-14 # 6 6 .75 .31 .27 .59 b134 1000 18-14 # 8 6 .72 .25 .27 .59 bc14-6 5 0 heavy duty 16-14 # 6 4 .81 .25 .29 .68 bc85 5 0 0 use c tooling # 6 4 .81 .25 .29 .68 bc14-8 5 0 heavy duty 16-14 # 8 4 .87 .39 .29 .68 bc86 5 0 0 use c tooling # 8 4 .87 .39 .29 .68 bc14-10 5 0 heavy duty 16-14 # 1 0 5 .87 .39 .29 .68 bc87 5 0 0 use c tooling #10 5 .87 .39 .29 .68 bc14-14 5 0 heavy duty 16-14 1 M 4 " 5 .93 .51 .29 .68 bc71 5 0 0 use c tooling 1 M 4 " 5 .93 .51 .29 .68 bc14-516 5 0 heavy duty 16-14 5 M 16 " 6 1.04 .54 .38 .77 bc72 5 0 0 use c tooling 5 M 16 " 6 1.04 .54 .38 .77 bc14-38 5 0 heavy duty 16-14 3 M 8 " 6 1.09 .63 .38 .77 bc79 5 0 0 use c tooling 3 M 8 " 6 1.09 .63 .38 .77 bc14-12 5 0 heavy duty 16-14 1 M 2 " 6 1.32 .76 .54 .94 bc75 5 0 0 use c tooling 1 M 2 " 6 1.32 .76 .54 .94 c10-6 5 0 12-10 # 6 4 .82 .31 .27 .66 c33 500 12-10 # 6 4 .82 .31 .27 .66 c10-8 5 0 12-10 # 8 5 .82 .31 .27 .66 c77 500 12-10 # 8 5 .82 .31 .27 .66 c10-10 5 0 12-10 #10 5 .85 .38 .27 .66 c26 500 12-10 #10 5 .85 .38 .27 .66 c36 1000 12-10 #10 7 .82 .31 .27 .66 c10-14 5 0 12-10 1 M 4 " 7 .91 .50 .27 .66 c71 500 12-10 1 M 4 " 7 .91 .50 .27 .66 c10-516 5 0 12-10 5 M 16 " 8 .98 .50 .38 .73 c70 500 12-10 5 M 16 " 8 .98 .50 .38 .73 c72 1000 12-10 5 M 16 " 7 1.10 .59 .45 .80 c10-38 5 0 12-10 3 M 8 " 7 1.10 .59 .45 .80 c73 500 12-10 3 M 8 " 7 1.10 .59 .45 .80 c10-12 5 0 12-10 1 M 2 " 7 1.21 .72 .38 .84 c75 500 12-10 1 M 2 " 7 1.21 .72 .38 .84 u.l. listed e9809 installing tools: wt111m, wt112m, wt110m, erg-2002, wt1300, wt2000, wt3155a these non-insulated ring terminals are made of electrolytic copper for high conductivity. they can be installed with crimping tools having a single indentor or double indentor (recom- mended for solid wire). serrated barrel increas- es grip on wire. wire range identification is stamped on the tongue of each terminal. most standard bulk catalog numbers can be put on mylar tape for reel fed applica- tions (i.e. 12050 tool and applicaton dies). consult tech service. please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) stock thickness: a & b = .03 bc = .05 c = .04 telecom 1-800-685-9452
non-insulated terminals 90 non-insulated ring wt./lbs. cat. pkg. wire bolt per dimensions no. qty. range hole 1000 a b c m d8-10 2 5 9-8-7 # 1 0 1 6 1.13 .48 .36 .90 d26* 2 0 0 9-8-7 # 1 0 1 6 1.13 .48 .36 .90 d8-14 2 5 9-8-7 1 M 4 " 1 4 1.13 .48 .36 .90 d71* 2 0 0 9-8-7 1 M 4 " 1 4 1.13 .48 .36 .90 d8-516 2 5 9-8-7 5 M 16 " 1 6 1.32 .59 .49 1.03 d72* 2 0 0 9-8-7 5 M 16 " 1 6 1.32 .59 .49 1.03 d8-38 2 5 9-8-7 3 M 8 " 1 4 1.32 .59 .49 1.03 d73* 2 0 0 9-8-7 3 M 8 " 1 4 1.32 .59 .49 1.03 d8-12 2 5 9-8-7 1 M 2 " 1 4 1.49 .82 .55 1.09 d75* 2 0 0 9-8-7 1 M 2 " 1 4 1.49 .82 .55 1.09 d10161 2 0 0 9-8-7 # 8 1 2 1.15 .41 .28 .95 d10361 2 0 0 9-8-7 # 1 0 1 2 1.15 .41 .28 .95 d10711 2 0 0 9-8-7 1 M 4 " 1 2 1.20 .45 .36 .97 d10721 2 0 0 9-8-7 5 M 16 " 1 2 1.28 .56 .36 1.00 d10731 2 0 0 9-8-7 3 M 8 " 1 2 1.28 .56 .36 1.00 d975* 2 0 0 9-8-7 1 M 2 " 1 2 1.46 .83 .49 1.06 e6-10 2 0 6-5 # 1 0 1 7 1.13 .48 .36 .90 e26* 2 0 0 6-5 # 1 0 1 7 1.13 .48 .36 .90 e6-14 2 0 6-5 1 M 4 " 2 0 1.13 .48 .36 .90 e71* 200 6-5 1 M 4 " 2 0 1.13 .48 .36 .90 e6-516 2 0 6-5 5 M 16 " 2 0 1.32 .60 .49 1.03 e72* 200 6-5 5 M 16 " 2 0 1.32 .60 .49 1.03 e6-38 2 0 6-5 3 M 8 " 2 0 1.32 .60 .49 1.03 e73* 200 6-5 3 M 8 " 2 0 1.32 .60 .49 1.03 e6-12 2 0 6-5 1 M 2 " 2 0 1.49 .82 .55 1.08 e75* 200 6-5 1 M 2 " 2 0 1.49 .82 .55 1.08 e10261 2 0 0 6-5 # 1 0 1 4 1.26 .49 .24 1.02 e10711 200 6-5 1 M 4 " 1 4 1.26 .49 .27 .99 e10721 200 6-5 5 M 16 " 1 4 1.38 .60 .34 1.04 e10731 200 6-5 3 M 8 " 1 4 1.38 .60 .34 1.04 f4-10 2 0 4-3 # 1 0 2 4 1.16 .48 .36 .93 f26* 2 0 0 4-3 # 1 0 2 4 1.16 .48 .36 .93 f4-14 2 0 4-3 1 M 4 " 2 5 1.16 .48 .36 .93 f71* 200 4-3 1 M 4 " 2 5 1.16 .48 .36 .93 f4-516 2 0 4-3 5 M 16 " 2 5 1.35 .60 .49 1.06 f72* 200 4-3 5 M 16 " 2 5 1.35 .60 .49 1.06 f4-38 2 0 4-3 3 M 8 " 2 5 1.35 .60 .49 1.06 f73* 200 4-3 3 M 8 " 2 5 1.35 .60 .49 1.06 f4-12 2 0 4-3 1 M 2 " 2 5 1.52 .82 .55 1.11 f75* 200 4-3 1 M 2 " 2 5 1.52 .82 .55 1.11 f10261 1 0 0 4-3 # 1 0 2 0 1.37 .55 .30 1.07 f10711 100 4-3 1 M 4 " 2 0 1.37 .55 .30 1.07 f10721 100 4-3 5 M 16 " 2 0 1.42 .62 .34 1.08 f10731 100 4-3 3 M 8 " 2 0 1.42 .62 .34 1.08 f975* 200 4-3 1 M 2 " 2 0 1.49 .83 .45 1.10 installing tools: wt115a d, e, f and g, wt3155a, (d-series only), tbm6/tbm6s, wt3175 installing dies: 11802 indentor (d-e-f-g), d-11803-nest, e-11805-nest, f-11806- nest (all ordered separately) note: not available on mylar tape. * brazed seam, lolly-pop style tongue c these non-insulated ring terminals are made of electrolytic copper for high conductivity. they can be installed with crimping tools having a single indentor or double indentor (recommend- ed for solid wire). serrated barrel increases grip on wire. wire range identification is stamped on the tongue of each terminal. stock thickness: d & e = .06 f = .07 d10, e10, f10 = .04 d975 & f975 = .04 telecom 1-800-685-9452
non-insulated terminals 91 non-insulated ring wt./lbs. cat. pkg. wire bolt per dimensions no. qty. range hole 1000 a b c m g2-14 1 0 2-1 1 M 4 " 5 0 1.59 .69 .40 1.26 g2-516 1 0 2-1 5 M 16 " 5 0 1.59 .69 .40 1.26 g2-38 1 0 2-1 3 M 8 " 5 0 1.59 .69 .40 1.26 g2-12 1 0 2-1 1 M 2 " 5 0 1.79 .80 .49 1.36 h10-14 10 1/0 1 M 4 " 5 0 1.65 .77 .43 1.32 j20-38 10 2/0 3 M 8 " 7 0 1.84 .83 .46 1.46 k30-38 5 3/0 3 M 8 " 8 2 2.08 .93 .54 1.69 l40-38 5 4/0 3 M 8 " 1 0 0 2.25 1.04 .57 1.77 m250-38 5 250mcm 3 M 8 " 1 3 5 2.40 1.12 .65 1.91 g926 1 0 0 1-2 # 1 0 4 0 1.59 .69 .40 1.26 g971 100 1-2 1 M 4 " 4 0 1.59 .69 .40 1.26 g972 100 1-2 5 M 16 " 4 0 1.59 .69 .40 1.26 g973 100 1-2 3 M 8 " 4 0 1.59 .69 .40 1.26 g975 100 1-2 1 M 2 " 4 0 1.79 .80 .49 1.36 g976 100 1-2 5 M 8 " 4 0 1.79 .80 .49 1.36 h971 100 1an-1/0 1 M 4 " 5 0 1.65 .77 .43 1.32 h972 100 1an-1/0 5 M 16 " 5 0 1.65 .77 .43 1.32 h973 100 1an-1/0 3 M 8 " 5 0 1.65 .77 .43 1.32 h975 100 1an-1/0 1 M 2 " 5 0 1.85 .77 .54 1.41 h976 100 1an-1/0 5 M 8 " 5 0 1.85 .77 .54 1.41 j971 100 1/0an-2/0 1 M 4 " 6 0 1.94 .84 .48 1.53 j972 100 1/0an-2/0 5 M 16 " 6 0 1.94 .84 .48 1.53 j973 100 1/0an-2/0 3 M 8 " 6 0 1.99 .84 .53 1.58 j974 100 1/0an-2/0 7 M 16 " 6 0 1.99 .89 .51 1.56 j975 100 1/0an-2/0 1 M 2 " 6 0 1.99 .89 .51 1.56 j976 100 1/0an-2/0 5 M 8 " 6 0 1.99 .89 .51 1.56 k971 100 2/0an-3/0 1 M 4 " 7 6 2.08 .93 .54 1.69 k972 100 2/0an-3/0 5 M 16 " 7 6 2.08 .93 .54 1.69 k973 100 2/0an-3/0 3 M 8 " 7 6 2.08 .93 .54 1.69 k974 100 2/0an-3/0 7 M 16 " 7 6 2.08 .93 .54 1.70 k975 100 2/0an-3/0 1 M 2 " 7 6 2.08 .93 .54 1.70 k976 100 2/0an-3/0 5 M 8 " 7 6 2.08 .93 .54 1.70 l973 100 3/0an-4/0 3 M 8 " 9 2 2.25 1.04 .57 1.77 l974 100 3/0an-4/0 7 M 16 " 9 2 2.25 1.04 .57 1.77 l975 100 3/0an-4/0 1 M 2 " 9 2 2.25 1.04 .57 1.77 l976 100 3/0an-4/0 5 M 8 " 9 2 2.25 1.04 .57 1.77 m972 100 4/0an-250mcm 5 M 16 " 1 1 2 2.28 1.12 .62 1.90 m973 100 4/0an-250mcm 3 M 8 " 1 1 2 2.40 1.12 .65 1.91 m974 100 4/0an-250mcm 7 M 16 " 1 1 2 2.40 1.12 .65 1.91 m975 100 4/0an-250mcm 1 M 2 " 1 1 2 2.40 1.12 .65 1.91 an aircraft wire installing tools: tbm6/tbm6s, wt3175 (g, h, j series only) note: not available on mylar tape. these non-insulated ring terminals are made of electrolytic copper for high conductivity. they can be installed with crimping tools having a single indentor or double indentor (recom- mended for solid wire). serrated barrel increas- es grip on wire. wire range identification is stamped on the tongue of each terminal. stock thickness: g & h = .05 j & k = .06 l & m = .07 telecom 1-800-685-9452
flag terminals 92 flag terminals allow a 90 connection to the terminal block without bending the wire. stock thickness: ab = .03 c = .04 d = .06 e = .06 f = .07 g = .08 non-insulated flag wt./lbs. cat. pkg. wire bolt per dimensions no. qty. range hole 1000 a b c m ab14-6a 100 22-14 # 6 2 1 M 2 .55 .31 .22 .39 ab51 1000 22-14 # 6 2 1 M 2 .55 .31 .22 .39 ab14-8a 100 22-14 # 8 2 1 M 2 .55 .31 .22 .39 ab52 1000 22-14 # 8 2 1 M 2 .55 .31 .22 .39 ab14-10a 100 22-14 #10 2 1 M 2 .55 .31 .22 .39 ab53 1000 22-14 #10 2 1 M 2 .55 .31 .22 .39 c51 500 12-10 # 6 5 .66 .31 .25 .48 c10-8a 5 0 12-10 # 8 5 .66 .31 .25 .48 c52 500 12-10 # 8 5 .66 .31 .25 .48 c10-10a 5 0 12-10 #10 5 .66 .31 .25 .48 c53 500 12-10 #10 5 .66 .31 .25 .48 d236 2 0 0 9,8,7 # 1 0 .83 .50 .25 .59 d226 2 0 0 9,8,7 # 1 0 .88 .50 .29 .64 d271 2 0 0 9,8,7 1 M 4 " .92 .50 .33 .68 e226 2 0 0 6,5 # 1 0 .93 .50 .29 .69 e271 200 6,5 1 M 4 " .97 .50 .33 .73 e272 200 6,5 5 M 16 " 1.05 .50 .41 .81 f226 2 0 0 4,3 # 1 0 1.07 .56 .33 .80 f271 200 4,3 1 M 4 " 1.10 .63 .33 .80 f272 200 4,3 5 M 16 " 1.18 .63 .41 .88 f273 200 4,3 3 M 8 " 1.20 .63 .43 .90 g671 100 2 1 M 4 " 1.20 .63 .33 .89 g672 100 2 5 M 16 " 1.28 .63 .41 .97 g673 100 2 3 M 8 " 1.32 .63 .46 1.02 u.l. listed e9809 installing tools: wt119, erg-2004, wt129 = d, e, f, g note: not available on mylar tape. telecom 1-800-685-9452
fork terminals 93 fork terminals with nylon insulation sleeves, recommended for temperatures up to 105?. inner bronze insulation grip sleeve lengthens flex radius of conductor and eliminates conduc- tor creep. nylon jacket is color-coded. stock thickness same as ring terminal of same size. nylon insulated fork?nsulation grip wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m ra18-6f 100 22-16 .136 # 6 3 .83 .25 .25 .71 ra1103 1000 22-16 .136 # 6 3 .83 .25 .25 .71 ra18-8f 100 22-16 .136 # 8 3 .86 .31 .25 .71 ra1123 1000 22-16 .136 # 8 3 .86 .31 .25 .71 ra18-10f 100 22-16 .136 # 1 0 3 .86 .31 .25 .71 ra1153 1000 22-16 .136 # 1 0 3 .86 .31 .25 .71 ra18-14f 100 22-16 .136 1 M 4 " 4 .95 .44 .31 .70 ra1163 1000 22-16 .136 1 M 4 " 4 .95 .44 .31 .70 rb14-6f 100 18-14 .162 # 6 3 1 M 2 .87 .31 .25 .71 rb1113 1000 18-14 .162 # 6 3 1 M 2 .87 .31 .25 .71 rb14-8f 100 18-14 .162 # 8 3 1 M 2 .87 .31 .25 .71 rb1123 1000 18-14 .162 # 8 3 1 M 2 .87 .31 .25 .71 rb14-10f 100 18-14 .162 # 1 0 4 .87 .38 .25 .71 rb1153 1000 18-14 .162 # 1 0 4 .87 .38 .25 .71 rb14-14f 100 18-14 .162 1 M 4 " 4 .95 .44 .28 .74 rb1163 1000 18-14 .162 1 M 4 " 4 .95 .44 .28 .74 rb1103 1000 18-14 .162 # 6 6 .74 .28 .16 .60 rb1124 1000 18-14 .190 # 8 6 .95 .31 .25 .79 rb1154 1000 18-14 .190 # 1 0 6 .95 .31 .25 .79 rc10-6f 5 0 12-10 .210 # 6 6 .97 .31 .27 .81 rc1113 500 12-10 .210 # 6 6 .97 .31 .27 .81 rc10-8f 5 0 12-10 .210 # 8 6 1.00 .37 .27 .81 rc1123 500 12-10 .210 # 8 6 1.00 .37 .27 .81 rc10-10f 5 0 12-10 .210 # 1 0 6 1.00 .37 .27 .81 rc1153 500 12-10 .210 # 1 0 6 1.00 .37 .27 .81 rc10-14f 5 0 12-10 .210 1 M 4 " 6 1.12 .50 .27 .86 rc1163 500 12-10 .210 1 M 4 " 6 1.12 .50 .27 .86 rc1124 1000 12-10 .250 # 8 6 1.10 .37 .27 .91 rc1154 1000 12-10 .250 # 1 0 6 1.10 .37 .27 .91 u.l. listed e9809 installing tools: wt145c, wt2000, wt112m, erg-2001, erg-2003, wt145a, wt2130a (rc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) telecom 1-800-685-9452
fork terminals nylon insulated fork flanged tongue?nsulation grip wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m ra18-6fs 100 22-16 .136 # 6 3 .75 .28 .16 .62 ra1203 1000 22-16 .136 # 6 3 .75 .28 .16 .62 ra18-8fs 100 22-16 .136 # 8 3 .89 .31 .23 .65 ra1223 1000 22-16 .136 # 8 3 .89 .31 .23 .65 ra18-10fs 100 22-16 .136 # 1 0 3 .93 .38 .26 .68 ra1253 1000 22-16 .136 # 1 0 3 .93 .38 .26 .68 rb14-6fs 100 18-14 .162 # 6 4 .74 .28 .16 .60 rb1203 1000 18-14 .162 # 6 4 .74 .28 .16 .60 rb14-8fs 100 18-14 .162 # 8 4 .89 .31 .23 .66 rb1223 1000 18-14 .162 # 8 4 .89 .31 .23 .66 rb14-10fs 100 18-14 .162 # 1 0 4 .94 .38 .27 .69 rb1253 1000 18-14 .162 # 1 0 4 .94 .38 .27 .69 rc10-8fs 5 0 12-10 .210 # 8 5 .97 .34 .23 .73 rc1223 500 12-10 .210 # 8 5 .97 .34 .23 .73 rc10-10fs 5 0 12-10 .210 # 1 0 5 1.00 .38 .26 .74 rc1253 500 12-10 .210 # 1 0 5 1.00 .38 .26 .74 rc1254 1000 12-10 .250 # 1 0 5 1.12 .38 .26 .86 u.l. listed e9809 installing tools: wt145c, wt2000, wt112m, erg-2001, erg-2003, wt145a, wt2130a (rc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) 94 turned up toes fork terminals allow easy installation because screw needs only to be loosened. suffix s indi- cates a flanged-tongue fork with turned up tips for extra holding protection. stock thickness same as ring terminal of same size. b c m a telecom 1-800-685-9452
fork terminals 95 these fork terminals have extra-long pvc insu- lation sleeve for protection and stress relief at wire? flex point. brazed seam barrel is serrated for high pull-out value. terminal is high con- ductivity electrolytic copper, electro-tin plated. insulation is color-coded. stock thickness same as ring terminal of same size. vinyl insulated fork?nsulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m 18ra-6f 100 22-16 .150 # 6 5 .94 .25 .27 .81 ra1167 1000 22-16 .150 # 6 5 .94 .25 .27 .81 18ra-8f 100 22-16 .150 # 8 5 .97 .31 .27 .81 ra1147 1000 22-16 .150 # 8 5 .97 .31 .27 .81 18RA-10f 100 22-16 .150 # 1 0 5 .97 .31 .27 .81 ra1157 1000 22-16 .150 # 1 0 5 .97 .31 .27 .81 14rb-6f 100 18-14 .170 # 6 6 .97 .31 .27 .81 rb647 1000 18-14 .170 # 6 6 .97 .31 .27 .81 14rb-6fs ? 100 18-14 .170 # 6 6 .89 .30 .25 .75 14rb-8f 100 18-14 .170 # 8 6 .97 .31 .27 .81 rb657 1000 18-14 .170 # 8 6 .97 .31 .27 .81 14rb-10f 100 18-14 .170 # 1 0 6 .97 .31 .27 .81 rb1157 1000 18-14 .170 # 1 0 6 .97 .31 .27 .81 14rb-14f 100 18-14 .170 1 M 4 " 6 1.11 .44 .38 .89 rb1717 1000 18-14 .170 1 M 4 " 6 1.11 .44 .38 .89 10rc-6f 5 0 12-10 .210 # 6 7 1.09 .38 .27 .90 rc1337 500 12-10 .210 # 6 7 1.09 .38 .27 .90 10rc-8f 5 0 12-10 .210 # 8 7 1.09 .38 .27 .90 rc1147 500 12-10 .210 # 8 7 1.09 .38 .27 .90 10rc-10f 5 0 12-10 .210 # 1 0 7 1.09 .38 .27 .90 rc1157 500 12-10 .210 # 1 0 7 1.09 .38 .27 .90 10rc-14f 5 0 12-10 .210 1 M 4 " 7 1.15 .50 .37 .90 rc1167 500 12-10 .210 1 M 4 " 7 1.15 .50 .37 .90 u.l. listed e9809 installing tools: wt145c, wt2000, wt112m, erg-2001, erg-2003, wt2130a (rc) ? turned-up toes most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) telecom 1-800-685-9452
fork terminals vinyl insulation fork?xpanded insulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m 18ra-6fx 100 22-16 .170 # 6 5 .94 .25 .27 .81 ra1167-170 1000 22-16 .170 # 6 5 .94 .25 .27 .81 18ra-8fx 100 22-16 .170 # 8 5 .97 .31 .27 .81 ra1147-170 1000 22-16 .170 # 8 5 .97 .31 .27 .81 18RA-10fx 100 22-16 .170 # 1 0 5 .97 .31 .27 .81 ra1157-170 1000 22-16 .170 # 1 0 5 .97 .31 .27 .81 14rb-6fx 100 18-14 .200 # 6 6 .97 .31 .27 .81 rb647-200 1000 18-14 .200 # 6 6 .97 .31 .27 .81 14rb-8fx 100 18-14 .200 # 8 6 .97 .31 .27 .81 rb657-200 1000 18-14 .200 # 8 6 .97 .31 .27 .81 14rb-10fx 100 18-14 .200 # 1 0 6 .97 .31 .27 .81 rb1157-200 1000 18-14 .200 # 1 0 6 .97 .31 .27 .81 10rc-8fx 5 0 12-10 .250 # 8 7 1.09 .38 .27 .90 rc1147-250 500 12-10 .250 # 8 7 1.09 .38 .27 .90 10rc-10fx 5 0 12-10 .250 # 1 0 7 1.09 .38 .27 .90 rc1157-250 500 12-10 .250 # 1 0 7 1.09 .38 .27 .90 10rc-14fx 5 0 12-10 .250 1 M 4 " 7 1.15 .50 .37 .90 u.l. listed e9809 installing tools: wt145c, wt2000, wt112m, erg2001, erg2003, wt2130a (rc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) 96 fork terminals allow easy installation since the mounting screw does not have to be completely removed. catalog numbers with the suffix x indicate an expanded insulation support. this means a wider wire entry to accommodate heavy wall insulation. stock thickness same as ring terminal of same size. telecom 1-800-685-9452
97 fork terminals non-insulated fork wt./lbs. cat. pkg. wire bolt per dimensions no. qty. range hole 1000 a b c m a18-6f 100 22-16 # 6 4 .72 .25 .27 .59 a116 1000 22-16 # 6 4 .72 .25 .27 .59 a18-8f 100 22-16 # 8 4 .75 .31 .27 .59 a114 1000 22-16 # 8 4 .75 .31 .27 .59 a18-10f 100 22-16 #10 4 .75 .31 .27 .59 a115 1000 22-16 #10 4 .75 .31 .27 .59 b14-6f 100 18-14 # 6 6 .75 .31 .27 .59 b64 1000 18-14 # 6 6 .75 .31 .27 .59 b19 ? 1000 18-14 # 6 6 .66 .25 .13 .50 b14-8f 100 18-14 # 8 6 .75 .31 .27 .59 b65 1000 18-14 # 8 6 .75 .31 .27 .59 b14-10f 100 18-14 #10 6 .75 .31 .27 .59 b115 1000 18-14 #10 6 .75 .31 .27 .59 b14-14f 100 18-14 1 M 4 " 6 .90 .44 .38 .68 c10-6f 5 0 12-10 # 6 7 .77 .31 .27 .63 c133 500 12-10 # 6 7 .77 .31 .27 .63 c10-8f 5 0 12-10 #10 7 .82 .38 .27 .63 c114 500 12-10 #10 7 .82 .38 .27 .63 c10-10f 5 0 12-10 #10 7 .82 .38 .27 .63 c115 500 12-10 #10 7 .82 .38 .27 .63 c10-14f 5 0 12-10 1 M 4 " 7 .98 .50 .37 .73 c116 5 0 12-10 1 M 4 " 7 1.15 .50 .37 .90 u.l. listed e9809 installing tools: wt111c, wt112m, wt110m, wt2000, erg2002, erg2003, wt1300, wt3155a ? turned-up toes most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) these non-insulated fork terminals are made of electrolytic copper for high conductivity. they can be installed with crimping tools having a single indentor or double indentor (recom- mended for solid wire). serrated barrel increase grip on wire. wire range identification is stamped on the tongue of each terminal. catalog numbers with the suffix s indicate a flanged-tongue fork with turned-up tips for extra holding protection in the event the mount- ing screw loosens. stock thickness same as ring terminal of same size. turned up toes telecom 1-800-685-9452
locking fork terminals nylon insulated locking fork?nsulation grip wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m ra18-6fl 100 22-16 .136 # 6 5 .86 .25 .25 .71 ra2213 1000 22-16 .136 # 6 5 .86 .25 .25 .71 ra18-8fl 100 22-16 .136 # 8 5 .86 .29 .25 .71 ra2243 1000 22-16 .136 # 8 5 .86 .29 .25 .71 ra18-10fl 100 22-16 .136 # 1 0 5 .86 .29 .25 .71 ra2253 1000 22-16 .136 # 1 0 5 .86 .29 .25 .71 rb14-6fl 100 18-14 .162 # 6 6 .87 .25 .25 .71 rb2213 1000 18-14 .162 # 6 6 .87 .25 .25 .71 rb2214 1000 18-14 .190 # 6 6 .95 .25 .25 .79 rb14-8fl 100 18-14 .162 # 8 6 .87 .29 .25 .71 rb2233 1000 18-14 .162 # 8 6 .87 .29 .25 .71 rb14-10fl 100 18-14 .162 # 1 0 6 .87 .29 .25 .71 rb2253 1000 18-14 .162 # 1 0 6 .87 .29 .25 .71 rb2254 1000 .190 # 1 0 6 .95 .29 .25 .71 rc10-6fl 5 0 12-10 .210 # 6 8 .97 .31 .27 .81 rc2203 500 12-10 .210 # 6 8 .97 .31 .27 .81 rc2204 1000 12-10 .250 # 6 8 1.07 .31 .27 .91 rc10-8fl 5 0 12-10 .210 # 8 8 1.00 .37 .27 .81 rc2213 500 12-10 .210 # 8 8 1.00 .37 .27 .81 rc10-10fl 5 0 12-10 .210 # 1 0 8 1.00 .37 .27 .81 rc2223 500 12-10 .210 # 1 0 8 1.00 .37 .27 .81 rc2224 1000 12-10 .250 # 1 0 1.10 .37 .27 .91 rc10-14fl 5 0 12-10 .210 1 M 4 " 8 1.12 .50 .32 .86 rc2233 500 12-10 .210 1 M 4 " 8 1.12 .50 .32 .86 u.l. listed e9809 u.s. pat. 3,590,387 installing tools: erg-2001, erg-2003, wt145c, wt2000, wt112m, wt145a, wt2130a (rc) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) 98 locking fork terminals have a spe- cially designed tongue that lets them go on like a fork and stay on like a ring. stock thickness same as ring terminal of same size. telecom 1-800-685-9452
terminals 99 locking fork terminals vinyl insulated locking fork?nsulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m 18ra-6fl 100 22-16 .150 # 6 5 .97 .25 .25 .81 ra2217 1000 22-16 .150 # 6 5 .97 .25 .25 .81 ra2227 1000 22-16 .155 # 6 5 .97 .29 .81 18ra-8fl 100 22-16 .150 # 8 5 .97 .29 .25 .81 ra2247 1000 22-16 .150 # 8 5 .97 .29 .25 .81 18RA-10fl 100 22-16 .150 # 1 0 5 .97 .29 .25 .81 ra2257 1000 22-16 .150 # 1 0 5 .97 .29 .25 .81 14rb-6fl 100 18-14 .170 # 6 6 .97 .25 .27 .81 rb2207 1000 18-14 .170 # 6 6 .97 .25 .27 .81 rb2217 1000 18-14 .170 # 6 6 .97 .29 .27 .81 14rb-8fl 100 18-14 .170 # 8 6 .97 .29 .27 .81 rb2237 1000 18-14 .170 # 8 6 .97 .29 .27 .81 14rb-10fl 100 18-14 .170 # 1 0 6 .97 .29 .27 .81 rb2257 1000 18-14 .170 # 1 0 6 .97 .29 .27 .81 10rc-6fl 5 0 12-10 .220 # 6 8 1.09 .31 .27 .90 rc2207 500 12-10 .220 # 6 8 1.09 .31 .27 .90 10rc-8fl 5 0 12-10 .220 # 8 8 1.09 .37 .27 .90 rc2217 500 12-10 .220 # 8 8 1.09 .37 .27 .90 10rc-10fl 5 0 12-10 .220 # 1 0 8 1.09 .37 .27 .90 rc2227 500 12-10 .220 # 1 0 8 1.09 .37 .27 .90 10rc-14fl 5 0 12-10 .220 1 M 4 " 8 1.09 .49 .27 .90 rc2237 500 12-10 .220 1 M 4 " 8 1.09 .49 .27 .90 u.l. listed e9809 u.s. pat. 3,590,387 installing tools: erg-2001, erg-2003, wt145c, wt2000, wt112m most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) stock thickness same as ring terminal of same size. telecom 1-800-685-9452
locking fork terminals vinyl insulated locking fork?xpanded insulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b c m 18ra-6flx 100 22-16 .170 # 6 5 .97 .25 .25 .81 18ra-8flx 100 22-16 .170 # 8 5 .97 .29 .25 .81 18RA-10flx 100 22-16 .170 # 1 0 5 .97 .29 .25 .81 ra2257-170 1000 22-16 .170 # 1 0 5 .97 .29 .25 .81 14rb-6flx 100 18-14 .200 # 6 6 .97 .31 .27 .81 rb2207-200 1000 18-14 .200 # 6 6 .97 .31 .27 .81 rb2217-200 1000 18-14 .200 # 6 6 .97 .29 .27 .81 14rb-8flx 100 18-14 .200 # 8 6 .97 .31 .27 .81 rb2237-200 1000 18-14 .200 # 8 6 .97 .31 .27 .81 14rb-10flx 100 18-14 .200 # 1 0 6 .97 .31 .27 .81 rb2257-200 1000 18-14 .200 # 1 0 6 .97 .31 .27 .81 10rc-6flx 5 0 12-10 .250 # 6 8 1.07 .31 .27 .91 rc2207-250 500 12-10 .250 # 6 8 1.07 .31 .27 .91 10rc-8flx 5 0 12-10 .250 # 8 8 1.10 .37 .27 .91 10rc-10flx 5 0 12-10 .250 # 1 0 8 1.10 .37 .27 .91 rc2227-250 500 12-10 .250 # 1 0 8 1.10 .37 .27 .91 10rc-14flx 5 0 12-10 .250 1 M 4 " 8 1.22 .50 .32 .96 u.l. listed e9809 u.s. pat. 3,590,387 installing tools: erg-2001, erg-2003, wt145c, wt2000, wt112m most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) heat shrinkable locking fork terminals expanded insulation support wt./lbs. cat. pkg. wire max. bolt per dimensions no. qty. range ins. hole 1000 a b ras18-6flx 100 22-18 .170 # 6 5 1.350 .25 ras18-8flx 100 22-18 .170 # 8 5 1.350 .29 ras18-10flx 100 22-18 .170 # 1 0 5 1.350 .29 rbs14-6flx 100 16-14 .200 # 6 6 1.350 .25 rbs14-8flx 100 16-14 .200 # 8 6 1.350 .29 rbs14-10flx 100 16-14 .200 # 1 0 6 1.350 .29 rcs10-6flx 5 0 12-10 .250 # 6 8 1.350 .31 rcs10-8flx 5 0 12-10 .250 # 8 8 1.350 .37 rcs10-10flx 5 0 12-10 .250 # 1 0 8 1.350 .37 rcs10-14flx 5 0 12-10 .250 1 M 4 " 8 1.350 .49 u.l. listed e9809 installing tool: wt1255 note: heat shrinkable terminals not available on mylar tape. 100 stock thickness same as ring terminal of same size. telecom 1-800-685-9452
terminals 101 locking fork terminals non-insulated locking fork wt./lbs. cat. pkg. wire bolt per dimensions no. qty. range hole 1000 a b c m a18-6fl 100 22-16 # 6 4 3 M 4 .75 .25 .27 .59 a221 1000 22-16 # 6 4 3 M 4 .75 .25 .27 .59 a18-8fl 100 22-16 # 8 4 3 M 4 .75 .29 .27 .59 a224 1000 22-16 # 8 4 3 M 4 .75 .29 .27 .59 a18-10fl 100 22-16 #10 4 3 M 4 .75 .29 .27 .59 a225 1000 22-16 #10 4 3 M 4 .75 .29 .27 .59 b14-6fl 100 18-14 # 6 4 3 M 4 .75 .25 .27 .59 b220 1000 18-14 # 6 4 3 M 4 .75 .25 .27 .59 b14-8fl 100 18-14 # 8 4 3 M 4 .75 .29 .27 .59 b223 1000 18-14 # 8 4 3 M 4 .75 .29 .27 .59 b14-10fl 100 18-14 #10 4 3 M 4 .75 .29 .27 .59 b225 1000 18-14 #10 4 3 M 4 .75 .29 .27 .59 c10-6fl 5 0 12-10 # 6 7 3 M 4 .85 .31 .27 .66 c220 500 12-10 # 6 7 3 M 4 .85 .31 .27 .66 c10-8fl 5 0 12-10 # 8 7 3 M 4 .85 .37 .27 .66 c221 500 12-10 # 8 7 3 M 4 .85 .37 .27 .66 c10-10fl 5 0 12-10 #10 7 3 M 4 .85 .37 .27 .66 c222-tb 500 12-10 #10 7 3 M 4 .85 .37 .27 .66 c10-14fl 5 0 12-10 1 M 4 "7 3 M 4 .85 .49 .27 .66 u.l. listed e9809 u.s. pat. 3,590,387 installing tools: wt110m, wt111m, wt112m, wt2000, erg-2002, wt1300, wt3155a (b&c) most standard bulk catalog numbers can be put on mylar tape for reel fed applications (i.e. 12050 tool and application dies). please put the suffix m for mylar tape ra2573m. (bulk number 1000 and 500 packages.) stock thickness same as ring terminal of same size. telecom 1-800-685-9452
heat shrinkable terminal, splices, disconnects heat shrinkable-ring terminals?xpanded insulation support wt./lbs. cat. pkg. wire max. bolt per no. qty. range ins. hole 1000 ras18-6x 100 22-18 .170 # 6 2 ras18-8x 100 22-18 .170 # 8 3 ras18-10x 100 22-18 .170 # 1 0 2 rbs14-6x 100 16-14 .200 # 6 3 rbs14-8x 100 16-14 .200 # 8 3 rbs14-10x 100 16-14 .200 # 1 0 3 rcs10-6x 5 0 12-10 .250 # 6 3 rcs10-8x 5 0 12-10 .250 # 8 5 rcs10-10x 5 0 12-10 .250 # 1 0 5 rcs10-14x 5 0 12-10 .250 1 M 4 "6 installing tool: wt1255 see previous pages for dimensional information. heat shrinkable-locking fork terminals expanded insulation support wt./lbs. cat. pkg. wire max. bolt per no. qty. range ins. hole 1000 ras18-6flx 100 22-18 .170 # 6 5 ras18-8flx 100 22-18 .170 # 8 5 ras18-10flx 100 22-18 .170 # 1 0 5 rbs14-6flx 100 16-14 .200 # 6 6 rbs14-8flx 100 16-14 .200 # 8 6 rbs14-10flx 100 16-14 .200 # 1 0 6 rcs10-6flx 5 0 12-10 .250 # 6 8 rcs10-8flx 5 0 12-10 .250 # 8 8 rcs10-10flx 5 0 12-10 .250 # 1 0 8 rcs10-14flx 5 0 12-10 .250 1 M 4 "8 installing tool: wt1255 note: not available on mylar tape. 102 heat shrinkable these ring terminals, butt splices and disconnects are self-insulated with heat shrinkable nylon and internally coated sealant. upon completed installation, a fully sealed connection is achieved to protect the joint against the degrading effects of galvanic action, corrosion, and environmen- telecom 1-800-685-9452


▲Up To Search▲   

 
Price & Availability of 18RA-10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X